Products

Pipe & Tank Heat Tracing

Not sure what you need? We can help. We offer complimentary specification and design services. Please contact us.

Heaters

Tresoeurs Design & Supply can provide any single cable length of up to 1000 feet for most self- regulating heater cables. We will cut to length for any project at no additional charge.

Self-Regulating Type Heater Cable: LT

Manufacturer: Nelson Heat Trace

Approvals: UL, FM, CSA

Applications: Freeze protection or process temperature maintenance for pipes and vessels.

Description: Self-regulating heater cable for use in ordinary or hazardous areas. Operating voltages from 120-277, output wattages from 3 watts per foot to 10 watts per foot.

Features: Flexible self-regulating heater with 16 gauge bus wires Approved for ordinary and hazardous locations, Div. 1 option Flouropolymer jacket option for corrosive environments Maintain temperatures to 150°F, exposure to 185°F

LT Brochure

Self Reg Manual

Self-Regulating Type Heater Cable: CLT

Manufacturer: Nelson Heat Trace

Approvals: C-UL-US, CSA

Applications:  Freeze protection or process temperature maintenance for pipes and vessels. Roof and gutter de-icing.

Description: Self-regulating heater cable for use in non-hazardous areas. Operating voltages from 120-277, output wattages from 3 watts per foot to 8 watts per foot.

Features: Flexible self-regulating heater with 18 gauge bus wires Tinned copper braid and outer polyolefin jacket Approved for fire protection lines Maintain temperatures to 150°F, exposure to 185°F

CLT Brochure

Self Reg Manual

Self-Regulating Type Heater Cable: HLT

Manufacturer: Nelson Heat Trace

Approvals: UL, FM, CSA

Applications:  Higher maintenance and exposure temperature for pipes and vessels.

Description: Self-regulating heater cable for use in ordinary or hazardous areas. Operating voltages from 120-277, output wattages from 3 watts per foot to 20 watts per foot.

Features: Flexible self-regulating heater with 16 gauge bus wires Approved for ordinary and hazardous locations, Div. 1 option Flouropolymer jacket option for corrosive environments Maintain temperatures to 250°F, exposure to 375°F

HLT Brochure

Self Reg Manual

Self-Regulating Type Heater Cable: QLT

Manufacturer: Nelson Heat Trace

Approvals: UL

Applications:  Higher maintenance and exposure temperature for pipes and vessels.

Description: Self-regulating heater cable for use in ordinary or hazardous areas. Operating voltages from 120-277, output wattages from 10 watts per foot to 20 watts per foot.

Features: Flexible self-regulating heater with 16 gauge bus wires Flouropolymer jacket option for corrosive environments Maintain temperatures to 250°F, exposure to 250°F

QLT Brochure

Self Reg Manual

Self-Regulating Type Heater Cable: LLT

Manufacturer: Nelson Heat Trace

Approvals: UL

Applications:  Process temperature maintenance for pipes and vessels.

Description: Self-regulating heater cable for water freeze protection and low watt density process temperature piping systems such as caustic lines. Extended circuit length for longer continuous runs. Can be applied to metal or plastic.

Features: Flexible self-regulating heater with 10 gauge bus wires Flouropolymer jacket option for corrosive environments Extended circuit lengths, up tp 1100 ft. Maintain temperatures to 150°F, exposure to 185°F

LLT Brochure

Self Reg Manual

Constant Wattage Type: MI

Manufacturer: Nelson Heat Trace

Approvals: UL, FM, CSA

Applications:  Higher maintenance and exposure temperature for pipes and vessels. Snow melting systems

Description: Magnesium oxide insulated cables with an incoloy sheath. Heaters are custom designed and assembled at the factory for project specific requirements. They provide constant, even watt density over the entire length of the cable. Ideal for high watt density and high temperature applications.

Features: Available in 120 to 600 volt applications Approved for ordinary and hazardous locations Factory pre-fabricated Rugged construction Maintain temperatures to 600°F, exposure to 1100°F

MI Brochure

MI Manual

Constant Wattage Type: VH-Panels

Manufacturer: Nelson Heat Trace

Approvals: FM

Applications:  Process temperature maintenance and freeze protection for tanks and vessels.

Description: VH silicone heating panels are suitable for use on metal tanks and vessels for maintain temperatures up to 175°F. Panels range in size and are rated up to 2000 watts.

Features: Available in 120 to 208/240 volt applications Approved for ordinary and C1,D2 hazardous locations Flexible for easy installation Maintain temperatures to 175°F

VH Brochure

VH Manual

Controls

Power: AP Panel

Manufacturer: Nelson Heat Trace

Approvals: UL

Applications:  Provide power and control to multiple heat trace cables Specifically designed for freeze protection applications Provides power distribution and on/off control for a group of heaters operating from a single controller.

Features: Built in main breaker and contactor. Power Available Light, Panel Energized Light, and HOA switch Available for 208/120, 240/120, and 480/277 volts Handles single pole and two pole branch breakers 30 mA GFEPD breakers available 120 through 277 volts NEMA 4 or 4X enclosures for wall or rack mounting

AP 240v Brochure

AP 480v Brochure

Power: DP Panel

Manufacturer: Nelson Heat Trace

Approvals: UL

Applications: Provide heat trace circuits with a dedicated power source These panels are typically used with systems utilizing multiple local line sensing controls

Features: Available for 208/120, 240/120, and 480/277 volts Handles single pole and two pole branch breakers 30 mA GFEPD breakers available 120 through 277 volts NEMA 4 or 4X enclosures for wall or rack mounting

DP 240v Brochure

DP 480v Brochure

Power: Custom Panels

We can design and manufacture heat trace control panels to your project specification. Please contact us.

Multi-Point Electronic Controls/Monitoring: CM-1

Manufacturer: Nelson Heat Trace

Approvals: FM, CSA Ordinary Locations

Type: Multi Circuit Monitor 12-48 Circuits Monitors voltage , current, and continuity

Power Input: 120 volts

Voltages: 120-600 volts

Enclosure Type: NEMA 4 or 4X Steel

Remote Monitoring: RS485 protocol

CM1 Brochure

CM1 Manual

Multi-Point Electronic Controls/Monitoring: CM-3

Manufacturer: Nelson Heat Trace

Approvals: ETL (pending) Class 1, Div. 2 Hazardous Locations

Type: Multi Circuit Control/Monitor 4-16 circuit configurations available

Voltages: 120-480 volts

Circuit Load: 30 amps

Temperature Range: 0-1000°F

Sensor Type: RTD (not included)

GF Heater Circuit Protection: Yes

Enclosure Type: NEMA 12, 4, 4X

Circuit Monitoring: Yes

Remote Monitoring: RS485 protocol

CM3 Brochure

CM3 Manual

Single Point Electronic Control: CM2001

Manufacturer: Nelson Heat Trace

Approvals: CSA Class 1, Div. 2 Hazardous Locations

Type: Line Sensing

Voltages: 120-277 volts

Circuit Load: 30 amps

Temperature Range: 0-932°F

Sensor Type: RTD (not included)

GF Heater Circuit Protection: Yes

Enclosure Type: NEMA 4X

Circuit Monitoring: Yes

Remote Monitoring: RS485 protocol

CM2001 Brochure

CM2001 Manual

Single Point Electronic Control: MS2101

Manufacturer: Nextron

Approvals: CSA, FM Class 1, Div. 2 Hazardous Locations

Type: Line Sensing

Voltages: 120-277 volts

Circuit Load: 30 amps

Temperature Range: 0-932°F

Sensor Type: RTD (not included)

GF Heater Circuit Protection: Yes

Enclosure Type: NEMA 4X

Circuit Monitoring: Yes

Remote Monitoring: RS485 protocol

MS2101 Brochure

Single Point Electronic Control: MS2102

Manufacturer: Nextron

Approvals: CSA, FM Class 1, Div. 2 Hazardous Locations

Type: 2 Circuit Line Sensing

Voltages: 120-277 volts

Circuit Load: 30 amps

Temperature Range: 0-932°F

Sensor Type: 2 RTD (not included)

GF Heater Circuit Protection: Yes

Enclosure Type: NEMA 4X

Circuit Monitoring: Yes

Remote Monitoring: RS485 protocol

MS2102 Brochure

Single Point Electronic Control: Tracemate

Manufacturer: Nextron

Approvals: CSA Class 1, Div. 2 Hazardous Locations

Type: Line Sensing

Voltages: 120-277 volts

Circuit Load: 30 amps

Temperature Range: 0-932°F

Sensor Type: RTD (included)

GF Heater Circuit Protection: Yes

Enclosure Type: NEMA 4X

Circuit Monitoring: Yes

Remote Monitoring: No

Tracemate Brochure

Single Point Electronic Control: TM II-CTR

Manufacturer: Nextron

Approvals: CSA Class 1, Div. 2 Hazardous Locations

Type: 2 Circuit Line Sensing

Voltages: 120-277 volts

Circuit Load: 30 amps

Temperature Range: 0-932°F

Sensor Type: 2 RTD (included)

GF Heater Circuit Protection: Yes

Enclosure Type: NEMA 4X

Circuit Monitoring: Yes

Remote Monitoring: No

TMII-CTR Brochure

Single Point Electronic Control: GPT-3

Manufacturer: Environmental Technology (ETI)

Approvals: C-UL-US Listed Ordinary Locations

Type: Line Sensing

Voltages: 120-277 volts

Circuit Load: 30 amps

Temperature Range: 41-77°F

Sensor Type: RTD (included)

GF Heater Circuit Protection: Yes

Enclosure Type: NEMA 3R

Circuit Monitoring: Yes

Remote Monitoring: No

GPT-3 Brochure

GPT-3 Manual

Single Point Electronic Control: SST-2

Manufacturer: Environmental Technology (ETI)

Approvals: C-UL-US Listed Ordinary Locations

Type: Line Sensing

Voltages: 120-277 volts

Circuit Load: 30 amps

Temperature Range: 40°F set point

Sensor Type: RTD (included)

GF Heater Circuit Protection: Yes

Enclosure Type: NEMA 4X

Circuit Monitoring: Yes

Remote Monitoring: No

SST-2 Brochure

SST-2 Manual

Temperature Probe: RTD-1

Description: Temperature probe, pipe mount

RTD1 Brochure

Temperature Probe: RTD-7

Description: Temperature probe, 7 ft. stainless steel lead

RTD7 Brochure

Temperature Probe: RTD-A

Description: Temperature probe, ambient mount

RTD-A Brochure

Mechanical T-Stat: TF4X40

Manufacturer: Nelson Heat Trace

Approvals: UL, CSA Ordinary Locations

Type: Ambient Sensing

Voltages: 120-480 volts

Circuit Load: 22 amps

Temperature Range: 40°F set point

Sensor Type: Bulb & Capillary

GF Heater Circuit Protection: No

Enclosure Type: NEMA 4X

TF4X40 Brochure

Mechanical T-Stat: TA4X140

Manufacturer: Nelson Heat Trace

Approvals: UL, CSA, CE Ordinary Locations

Type: Ambient Sensing

Voltages: 120-480 volts

Circuit Load: 22 amps

Temperature Range: 15-140°F

Sensor Type: Bulb & Capillary

GF Heater Circuit Protection: No

Enclosure Type: NEMA 4X

TA4X140 Brochure

Mechanical T-Stat: TA7140

Manufacturer: Nelson Heat Trace

Approvals: UL, CSA, FM Class 1, Div. 1 Hazardous Locations

Type: Ambient Sensing

Voltages: 120-480 volts

Circuit Load: 22 amps

Temperature Range: 15-140°F

Sensor Type: Bulb & Capillary

GF Heater Circuit Protection: No

Enclosure Type: NEMA 4, 7, 9

TA7140 Brochure

Mechanical T-Stat: TH4X325

Manufacturer: Nelson Heat Trace

Approvals: UL, CSA Ordinary Locations

Type: Line Sensing

Voltages: 120-480 volts

Circuit Load: 22 amps

Temperature Range: 15-325°F

Sensor Type: Bulb & Capillary

GF Heater Circuit Protection: No

Enclosure Type: NEMA 4X Links: TH4X325 Brochure

TH4X325 Brochure

Mechanical T-Stat: TH7325

Manufacturer: Nelson Heat Trace

Approvals: UL, CSA, FM Class 1, Div. 1 Hazardous Locations

Type: Line Sensing

Voltages: 120-480 volts

Circuit Load: 22 amps

Temperature Range: 15-325°F

Sensor Type: Bulb & Capillary

GF Heater Circuit Protection: No

Enclosure Type: NEMA 4, 7, 9

TH7325 Brochure

Mechanical T-Stat: TH4X600

Manufacturer: Nelson Heat Trace

Approvals: UL, CSA Ordinary Locations

Type: Line Sensing

Voltages: 120-480 volts

Circuit Load: 22 amps

Temperature Range: 320-600°F

Sensor Type: Bulb & Capillary

GF Heater Circuit Protection: No

Enclosure Type: NEMA 4X

TH4X600 Brochure

Mechanical T-Stat: TH7600

Manufacturer: Nelson Heat Trace

Approvals: UL, CSA Class 1, Div. 1 Hazardous Locations

Type: Line Sensing

Voltages: 120-480 volts

Circuit Load: 22 amps

Temperature Range: 320-600°F

Sensor Type: Bulb & Capillary

GF Heater Circuit Protection: No

Enclosure Type: NEMA 4, 7, 9

TH7600 Brochure

Mechanical T-Stat: TE4X60

Manufacturer: Nelson Heat Trace

Approvals: UL, CSA, FM Ordinary Locations

Type: Line Sensing

Voltages: 120 volts

Circuit Load: 8 amps

Temperature Range: 32-1000°F

Sensor Type: Thermocouple

GF Heater Circuit Protection: No

Enclosure Type: NEMA 4X

TE4X60 Brochure

Mechanical T-Stat: TE760

Manufacturer: Nelson Heat Trace

Approvals: UL, CSA Class 1, Div. 1 Hazardous Locations

Type: Line Sensing

Voltages: 120-480 volts

Circuit Load: 22 amps

Temperature Range: 32-1000°F

Sensor Type: Thermocouple

GF Heater Circuit Protection: No

Enclosure Type: NEMA 4, 7, 9

TE760 Brochure

Accessories

Connection Kit: PLT

Manufacturer: Nelson Heat Trace

Enclosure: Non-Metallic

Approvals: UL, CSA Class 1, Div. 2 Areas

Applications: Pipes and Tanks

PLT Brochure

Connection Kit: PLT-BCT

Manufacturer: Nelson Heat Trace

Enclosure: Lighted Connection Kit Non-Metallic

Approvals: UL, CSA Class 1, Div. 2 Areas

Applications: Pipes and Tanks

Connection Kit: ALT

Manufacturer: Nelson Heat Trace

Enclosure: Metallic

Approvals: UL, CSA Class 1, Div. 2 Areas

Applications: Pipes and Tanks Links: ALT Brochure

ALT Brochure

Connection Kit: HASK

Manufacturer: Nelson Heat Trace

Enclosure: Metallic- Hazardous areas

Approvals: UL, CSA Class 1, Div. 1 Areas

Applications: Pipes and Tanks

HASK Brochure

Connection Kit: HCP1-S-E

Manufacturer: Nelson Heat Trace

Description: Connection kit with GF Protection

Applications: Pipes, Tanks, Roof and Gutter

HCP1-S-E Brochure

Connection Kit: PCK

Manufacturer: Nelson Heat Trace

Description: Molded Silicone Power & End Seals w/Adhesive

Applications: Pipes & Tanks

PCK Brochure

PCK Installation

End Kit: PLT-L

Manufacturer: Nelson Heat Trace

Enclosure: Lighted End Kit Non-Metallic

Approvals: UL, CSA Class 1, Div. 2 Areas

Applications: Pipes and Tanks

PLT-L Brochure

Connection Components: LT-MP

Description: Molded Silicone Power Seals - Package of 5

Manual

Connection Components: LT-ME

Description: Molded Silicone End Seals - Package of 5

Manual

Connection Components: LT-SP

Description: Shrink Wrap Power Seals - Package of 5

Manual

Connection Components: LT-SE

Description: Shrink Wrap End Seals - Package of 5

Manual

Connection Components: LT-SS

Description: Shrink Wrap Splice - Package of 5

Manual

Connection Components: LT-ST

Description: Shrink Wrap Tee - Package of 5

Manual